Ahad,

The Cores have
Connections to other POPs
Transiting
IX circuits connected on them
Also have some Customer on them so they do also act like a PE.

Thanks

Erik

Erik Sundberg
Sr. Network Engineering
Network Engineering Department
p: 773.661.5532
c: 708.710.7419
e: esundb...@nitelusa.com
Main: 888.450.2100
NOC 24/7: 866.892.0915
350 North Orleans Street, Suite 1300N Chicago, IL 60654
www.nitelusa.com<http://www.nitelusa.com/>
[Nitel]
Managed Telecom Services
MPLS | Ethernet | Private Line | Internet | Voice | Security

From: Ahad Aboss [mailto:a...@swiftelnetworks.com]
Sent: Friday, May 4, 2018 9:16 AM
To: Erik Sundberg <esundb...@nitelusa.com>
Cc: NANOG <nanog@nanog.org>
Subject: Re: Route Reflector Client Design Question

Erik,

Before I email my suggestions, can you clarify the followings;

Do Core1 and Core2 also provide the function of BDRs peering with your 
upstream/s?

Or

Just acting as Core/RRs with 500Mbps of traffic traversing through them?

Cheers
Ahad


On Fri, May 4, 2018 at 4:01 PM, Erik Sundberg 
<esundb...@nitelusa.com<mailto:esundb...@nitelusa.com>> wrote:
I have a RR Client design question......


CORE1-------------------2x10G-----------------------CORE2
|                                                                               
    |
|                                                                               
    |
|                                10G Ring                                   |
|                                                                               
    |
|                                                                               
    |
PE1----------PE2----------PE3----------PE4----------PE5


-Core1 & Core2 are RR Reflectors with full IPV4 Tables (ASR9K)
-MPLS LDP Enabled
-IGP is ISIS
-Each PE peers only with Core1 and Core2 as RR Clients with iBGP
-PE's are only receiving a default route from the Core Routers due to TCAM size 
of 20K (ASR920's\ME3800's)
-The ring does not have that much traffic on it <500m, so I do not want to use 
additional 10G ports on the Core's and is why I have it in a 10G U ring.
-Primary link to the cores is via the PE1 --- CORE1 Like......... For this 
discussion the link between PE5 to CORE2 is set up as a backup link.

The scenario is I have traffic between PE2 and PE3. Since the PE's are only 
receiving a default route from the Cores. Traffic is label switch from PE2 - 
PE1 - Core1 does a IP lookup at Ingress then label switches back to 
PE1-PE2-PE3. This ends up being 5 hops and doubling the traffic on the link to 
the Cores.

My questions is how do I get traffic to go directly between the PE's without 
going to the Core Routers?

1. Can I enable iBGP between the PE's in a full mesh to allow traffic between 
the PE's without going to the core's. Or does this break the Route Reflector 
model?
2. Create a route policy on the Core's advertising routes learned from the PE's 
back to all the PE's on the ring.
3. Is this one of the down sides to U Rings?
4. Leave it alone and move on to bigger and better things....


Thanks

Erik

________________________________

CONFIDENTIALITY NOTICE: This e-mail transmission, and any documents, files or 
previous e-mail messages attached to it may contain confidential information 
that is legally privileged. If you are not the intended recipient, or a person 
responsible for delivering it to the intended recipient, you are hereby 
notified that any disclosure, copying, distribution or use of any of the 
information contained in or attached to this transmission is STRICTLY 
PROHIBITED. If you have received this transmission in error please notify the 
sender immediately by replying to this e-mail. You must destroy the original 
transmission and its attachments without reading or saving in any manner. Thank 
you.


________________________________

CONFIDENTIALITY NOTICE: This e-mail transmission, and any documents, files or 
previous e-mail messages attached to it may contain confidential information 
that is legally privileged. If you are not the intended recipient, or a person 
responsible for delivering it to the intended recipient, you are hereby 
notified that any disclosure, copying, distribution or use of any of the 
information contained in or attached to this transmission is STRICTLY 
PROHIBITED. If you have received this transmission in error please notify the 
sender immediately by replying to this e-mail. You must destroy the original 
transmission and its attachments without reading or saving in any manner. Thank 
you.

Reply via email to