Depends on how and where you disconnected the trigger - may need to load down 
that pin.
Can you confirm that lifting the wiper DOES trigger the tube?   You could set 
up the right conditions on the other pins [including trigger] and then 
interrupt that circuit manually.
If it is a 'glitch' from the wiper, a capacitor/resistor network should improve 
things. 
Let's see what is forthcoming from all the others here.
John K
Australia
  ----- Original Message ----- 
  From: bob harper 
  To: neonixie-l@googlegroups.com 
  Sent: Thursday, March 27, 2014 6:34 PM
  Subject: [neonixie-l] Re: trigger tube equivilents


  hi all...well i have finally got this thing working...all trigger tubes, in 
the selection system the countdown tubes in the credit unit and the 3 digital 
display nixie tubes...but ONE remaining problem. the 1st tube on the left in 
the schematic a GR44 [i have tried another as well] fires when it should, but 
also when it should not, i disconnected the trigger and it still fires...the 
problem [i think] is that the K cathode is connected via a wiper contact on a 
rotating arm to the reset solenoid, which although cleaned and adjusted and 
tested with the meter, must be occasionally losing its contact [bear in mind 
the etched track is 50 years old] for a split second.......clip.....

-- 
You received this message because you are subscribed to the Google Groups 
"neonixie-l" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to neonixie-l+unsubscr...@googlegroups.com.
To post to this group, send an email to neonixie-l@googlegroups.com.
To view this discussion on the web, visit 
https://groups.google.com/d/msgid/neonixie-l/A7552ABCC17545249339C8D11AEDCD0B%40compunet4f9da9.
For more options, visit https://groups.google.com/d/optout.

Reply via email to