Hi, Dave Thank you for give me the guidance. Another question, I write trapsink 172.18.100.148 public 162 in snmpd.conf, after I run snmpd and send the trap, I can get the trap in 172.18.100.148. Then, I modify the snmpNotifyType from 1(trap) to 2(inform), and send the trap again, but I still receive the trap but not the inform in 172.18.100.148. I wondered should I do anything to let the configuration take effective after I change snmpNotifyType?
-----邮件原件----- 发件人: [email protected] [mailto:[email protected]] 代表 Dave Shield 发送时间: 2009年4月14日 16:24 收件人: Kang Chen 抄送: [email protected] 主题: Re: question about SNMPv3 trap 2009/4/14 Kang Chen <[email protected]>: > I want to know, if I haven’t write it in the snmpd.conf, I want to > configure it with the mibbrowser, if it is possible and which mib table > support this feature? Yes - it's possible. The MIB tables you would need to set up are SNMP-TARGET-MIB::snmpTargetAddrTable SNMP-TARGET-MIB::snmpTargetParamsTable SNMP-NOTIFICATION-MIB::snmpNotifyTable Try setting up the target via the snmpd.conf file, and then walk these three tables to see (and understand) the contents. Dave ------------------------------------------------------------------------------ This SF.net email is sponsored by: High Quality Requirements in a Collaborative Environment. Download a free trial of Rational Requirements Composer Now! http://p.sf.net/sfu/www-ibm-com _______________________________________________ Net-snmp-coders mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/net-snmp-coders