On 06/11/2007, Andreas Mueller <[EMAIL PROTECTED]> wrote:
> I set the timeout in the open and register PDU to 15 seconds (to have 
> some time for debugging), but it seems that the snmpd ignores these 
> settings. It seems to repeat the request in 1 second interval 5 times 
> and then closes the session to my agentx subagent.

Dave wrote:
> How are you setting these timeout values?

I have my own implementation of an AgentX subagent. I test it against
some
SNMPD implementations (one of them is NET-SNMP).

> There's an snmpd.conf directive "agentxTimeout" which might be helpful
to you.

OK, that might be helpful for debugging. But what should I do when I
cannot
guarantee a response time of 1 second and want to tell the master agent
that
it should use a greater timeout (the AgentX code runs in a separate
thread
and must synchronize (mutex) against other threads that may hold the
mutex
for a view seconds (e.g. when synchronizing data to disk))? The RFC
mentions
the timeout in the open and register PDU that should overwrite the
default
timeout.

Andreas

-------------------------------------------------------------------------