Dave Shield wrote:
> On 18/04/2008, Thomas Anders <[EMAIL PROTECTED]> wrote:
>> Then, still, shouldn't the disman code work independent of MIBS settings?
> 
> If it's set up using numeric OIDs, then yes - it would.
> If it's configured using MIB object names, then it relies on the
> library MIB parser to translate those names into numeric OIDs.
> 
> Remember that it's just the snmpd.conf processing that's relevant
> here.  The DisMan tables themselves work with numeric OIDs.

I fully agree that's how it should work. But didn't the original poster say 
that just including "linkUpDownNotifications yes" in snmpd.conf triggered the 
ifOperStatus error?

Here's a quick test:

foo# env MIBS="" /path/to/snmpd --linkupdownnotifications=yes 
--agentsecname=_internal --rouser=_internal --rocommunity=foobar -C -c 
/dev/null -f -Le localhost:8161
trigger OID: ifOperStatus

: line 0: Error: unknown monitor OID
trigger OID: ifOperStatus

: line 0: Error: unknown monitor OID
[...]

Am I missing something obvious?