Thanks Dave, that fixed the problem:) I know it is a bit after the fact, but do 
you want me to put in a bug for tracability?

Regards,
Richard.

-----Original Message-----
From: dave.shi...@googlemail.com [mailto:dave.shi...@googlemail.com] On Behalf 
Of Dave Shield
Sent: Thursday, 14 May 2009 1:49 AM
To: Richard Gipps
Cc: net-snmp-users@lists.sourceforge.net
Subject: Re: Using the monitor function with thresholds

2009/5/13 Richard Gipps <richa...@triodatacom.com>:
>                 I have been using the monitor function with positive 
> thresholds and it works well. When I try to use it with negative 
> thresholds it does not seem to work at all (doesn't send traps).

Hmmm.....   I have a horrible feeling that you are quite correct.
Can you please try the attached patch, and see whether this fixes things for 
you.

Dave

------------------------------------------------------------------------------