2009/7/23 François Dumont <francoisdumon...@gmail.com>: >> snmpset -c private -v 2c 10.0.0.1 rbAQoSProfileRowStatus.32 i 4 >> rbQoSProfileType.32 i 1 rbQoSProfileName.32 s test rbQoSProfileParamTime.32 >> i 1 rbQoSProfileParam1.32 u 1000 > > And it worked....
> But then I tried to set another row and now I can't :/ I don't know why, I > do exactly the same thing and it doesn't work : > >> snmpset -c private -v 2c 10.0.0.1 rbAQoSProfileRowStatus.39 i 4 >> rbQoSProfileType.39 i 1 rbQoSProfileName.39 s test rbQoSProfileParamTime.39 >> i 1 rbQoSProfileParam1.39 u 1000 >> Error in packet. >> Reason: undoFailed >> Failed object: RAINBOW-SERVICE-MIB::rbAQoSProfileParam1.39 > > Can someone help me ? Does the MIB allow multiple profiles to have the same name? Try a different value for "rbQoSProfileName" Dave ------------------------------------------------------------------------------ _______________________________________________ Net-snmp-users mailing list Net-snmp-users@lists.sourceforge.net Please see the following page to unsubscribe or change other options: https://lists.sourceforge.net/lists/listinfo/net-snmp-users