2009/11/26 Mudassar <mudas...@innovative-pk.com>:
> I am trying to trigger an event on physical memory and add the following
> line in snmpd.conf, all other events are working perfect
>
> monitor -u _internal -r 2 "Low Physical Memory" -o hrMemorySize
>     hrStorageUsed.1 > 1100000

Do the other events use the same "-u" user?
Given that this is a single-instance monitor,
  it might be sensible to use the -I flag.

If that doesn't work, then some more information about the
events that *do* work might be useful

Dave

------------------------------------------------------------------------------