Hi Mike,
thanks for reply!
Is there any chance to change the code for OSPF-MIB, to make it writeble?
Does this mean that all protocols (RIP,OSPF and BGP) that are supported by SMUX
are only from monitoring?
Best regards!
Nina
--- On Thu, 1/7/10, Mike Ayers <mike_ay...@tva.tvworks.com> wrote:
From: Mike Ayers <mike_ay...@tva.tvworks.com>
Subject: RE: snmpset - OSPF-MIB
To: "Nina Cukic" <ninacu...@yahoo.co.uk>, net-snmp-users@lists.sourceforge.net
Date: Thursday, 1 July, 2010, 1:20
> From: Nina Cukic [mailto:ninacu...@yahoo.co.uk]
> Sent: Wednesday, June 30, 2010 4:07 PM
> Well I am still having problem with snmpset when I am usig to change
> variables in OSPF-MIB.
>
> I have a quetion:
>
> Does the line in code snmp_ospf.c:
>
> /*
> * No writes for now
> */
> *write_method = NULL;
>
> /*
>
> means that it is forbidden to write in read-write or read-create
> objects.
Yep. The module provides no way to change its values. That's actually
common in the SNMP world - monitor-only MIBs.
HTH,
Mike
------------------------------------------------------------------------------