On 3 August 2012 12:54, Edgar <[email protected]> wrote:
> I want to translate this:
> .1.3.6.1.4.1.232.6.2.9.3.1.5.0.2 = INTEGER: 1
> into this:
> CPQHLTH-MIB::cpqHeFltTolPowerSupplyStatus.0.2 = INTEGER: noError(1)
As long as the CPQHLTH-MIB is installed properly (and being read in)
then this should be handled automatically.
Where is the file 'CPQHLTH-MIB.txt' ?
Try copying this MIB to the directory /usr/share/snmp/mibs
and add the option
+CPQHLTH-MIB
to the snmpget/snmpwalk command you are using.
Dave
------------------------------------------------------------------------------