On 3 August 2012 12:54, Edgar <[email protected]> wrote:
> I want to translate this:
>     .1.3.6.1.4.1.232.6.2.9.3.1.5.0.2 = INTEGER: 1
> into this:
>     CPQHLTH-MIB::cpqHeFltTolPowerSupplyStatus.0.2 = INTEGER: noError(1)

As long as the CPQHLTH-MIB is installed properly (and being read in)
then this should be handled automatically.

Where is the file 'CPQHLTH-MIB.txt' ?
Try copying this MIB to the directory /usr/share/snmp/mibs
and add the option

    +CPQHLTH-MIB

to the snmpget/snmpwalk command you are using.

Dave

------------------------------------------------------------------------------