On 10 September 2012 18:49, Manjul Rai <manjul....@gmail.com> wrote:
> I have read the man pages and it seems that the monitor statement only
> accepts one expression.  I would love to find out if there is any way to do
> AND/OR logic in the monitor statement.

That's essentially the purpose of the DisMan Expression MIB.
You'd configure an entry within the expExpressionTable to track
the AND/OR logic on the object(s) of interest, and then have
a "monitor" statement watching the expValueTable.

  There is a preliminary implementation of this MIB within the Net-SNMP
agent, but it's never really had much use or feedback, so I wouldn't like
to say how complete or solid it might be.  But that's definitely the way
that things are meant to work.

Trylooking at this, and feed back your experiences to the
active developers.