There is an error "e1000e: probe of 0000:00:19.0 failed with error -3"
that can be observed after power-on on some I218 controllers.
Hardware reset and re-initialization fixes the issue.

Signed-off-by: Denis Turischev <denis.turisc...@compulab.co.il>

diff -Nru linux-4.7.orig/drivers/net/ethernet/intel/e1000e/ich8lan.c 
linux-4.7/drivers/net/ethernet/intel/e1000e/ich8lan.c
--- linux-4.7.orig/drivers/net/ethernet/intel/e1000e/ich8lan.c  2016-07-24 
22:23:50.000000000 +0300
+++ linux-4.7/drivers/net/ethernet/intel/e1000e/ich8lan.c       2016-08-01 
13:59:08.046563095 +0300
@@ -155,6 +155,7 @@
 static s32 e1000_disable_ulp_lpt_lp(struct e1000_hw *hw, bool force);
 static s32 e1000_setup_copper_link_pch_lpt(struct e1000_hw *hw);
 static s32 e1000_oem_bits_config_ich8lan(struct e1000_hw *hw, bool d0_state);
+static s32 e1000_reset_hw_ich8lan(struct e1000_hw *hw);
 
 static inline u16 __er16flash(struct e1000_hw *hw, unsigned long reg)
 {
@@ -459,8 +460,12 @@
        phy->id = e1000_phy_unknown;
 
        ret_val = e1000_init_phy_workarounds_pchlan(hw);
-       if (ret_val)
-               return ret_val;
+       if (ret_val) {
+               e1000_reset_hw_ich8lan(hw);
+               ret_val = e1000_init_phy_workarounds_pchlan(hw);
+               if (ret_val)
+                       return ret_val;
+       }
 
        if (phy->id == e1000_phy_unknown)
                switch (hw->mac.type) {

Reply via email to