From: Thomas Falcon <tlfal...@linux.vnet.ibm.com>
Date: Wed, 15 Feb 2017 10:32:11 -0600

> When a vNIC client driver requests a faulty device setting, the
> server returns an acceptable value for the client to request.
> This 64 bit value was incorrectly being swapped as a 32 bit value,
> resulting in loss of data. This patch corrects that by using
> the 64 bit swap function.
> 
> Signed-off-by: Thomas Falcon <tlfal...@linux.vnet.ibm.com>

Applied.