On Thu, 2017-12-07 at 16:46 +0100, Andrew Lunn wrote: > On Thu, Dec 07, 2017 at 03:27:10PM +0100, Jerome Brunet wrote: > > Add read and write helpers to manipulate banked registers on this PHY > > This helps clarify the settings applied to these registers in the init > > function and upcoming changes. > > > > Signed-off-by: Jerome Brunet <jbru...@baylibre.com> > > --- > > drivers/net/phy/meson-gxl.c | 103 ++++++++++++++++++++++++++++------------- > > --- > > 1 file changed, 67 insertions(+), 36 deletions(-) > > > > diff --git a/drivers/net/phy/meson-gxl.c b/drivers/net/phy/meson-gxl.c > > index d82aa8cea401..05054770aefb 100644 > > --- a/drivers/net/phy/meson-gxl.c > > +++ b/drivers/net/phy/meson-gxl.c > > @@ -45,11 +45,13 @@ > > #define FR_PLL_DIV0 0x1c > > #define FR_PLL_DIV1 0x1d > > > > -static int meson_gxl_config_init(struct phy_device *phydev) > > +static int meson_gxl_open_banks(struct phy_device *phydev) > > Hi Jerome > > Does the word bank come from the datasheet? Most of the phy drives use > page instead. > > Also, we have discovered a race condition which affects drivers using > pages, which can lead to corruption of registers. At some point, i > expect we will be adding helpers to access paged registers, which do > the right thing with respect to locks. > > So it would be nice if you used the work page, not bank.
Banks actually comes from the datasheet, Yes. I don't mind renaming it but I would be making things up. As you wish ? Does the usual pages comes with this weird toggle thing to open the access ? Would we able to use these generic helpers with our this kind of quirks ? > > Thanks > > Andrew