From: Marco Felsch <[email protected]> Date: Tue, 15 May 2018 10:18:56 +0200
> From: Markus Niebel <[email protected]> > > The micrel KSZ9031 phy has a optional clock pin (CLK125_NDO) which can be > used as reference clock for the MAC unit. The clock signal must meet the > RGMII requirements to ensure the correct data transmission between the > MAC and the PHY. The KSZ9031 phy does not fulfill the duty cycle > requirement if the phy is configured as slave. For a complete > describtion look at the errata sheets: DS80000691D or DS80000692D. > > The errata sheet recommends to force the phy into master mode whenever > there is a 1000Base-T link-up as work around. Only set the > "micrel,force-master" property if you use the phy reference clock provided > by CLK125_NDO pin as MAC reference clock in your application. > > Attenation, this workaround is only usable if the link partner can > be configured to slave mode for 1000Base-T. > > Signed-off-by: Markus Niebel <[email protected]> > [[email protected]: fix dt-binding documentation] > [[email protected]: use already existing result var for read/write] > [[email protected]: add error handling] > [[email protected]: add more comments] > Signed-off-by: Marco Felsch <[email protected]> Applied, thank you.