Le 06/04/18 à 13:17, Kun Yi a écrit :
> BCM54612E have 4 multi-functional LED pins that can be configured
> through register setting; the LED4 pin can be configured to a 125MHz
> reference clock output by setting the spare register. Since the dedicated
> CLK125 reference clock pin is not brought out on the 48-Pin MLP, the LED4
> pin is the only pin to provide such function in this package, and therefore
> it is beneficial to just enable the reference clock by default.

Checked the data sheet and this appears to be absolutely correct:

Reviewed-by: Florian Fainelli <f.faine...@gmail.com>
-- 
Florian

Reply via email to