From: Andrew Lunn <and...@lunn.ch>
Date: Sun, 11 Nov 2018 00:50:39 +0100

> We already have a workaround for a couple of switches whose internal
> PHYs only have the Marvel OUI, but no model number. We detect such
> PHYs and give them the 6390 ID as the model number. However the
> mv88e6161 has two SERDES interfaces in the same address range as its
> internal PHYs. These suffer from the same problem, the Marvell OUI,
> but no model number. As a result, these SERDES interfaces were getting
> the same PHY ID as the mv88e6390, even though they are not PHYs, and
> the Marvell PHY driver was trying to drive them.
> 
> Add a special case to stop this happen.
> 
> Reported-by: Chris Healy <chris.he...@zii.aero>
> Signed-off-by: Andrew Lunn <and...@lunn.ch>

Please address Sergei's feedback, thank you.

Reply via email to