The current bcm63xx_enet driver doesn't asign the internal phy IRQ. As a
result of this it works in polling mode.
Fix it using the phy_device structure to assign the platform IRQ.
Tested under a BCM6348 board. Kernel dmesg before the patch:
Broadcom BCM63XX (1) bcm63xx_enet-0:01: attached PHY driver [Broadcom
BCM63XX (1)] (mii_bus:phy_addr=bcm63xx_enet-0:01, irq=POLL)
After the patch:
Broadcom BCM63XX (1) bcm63xx_enet-0:01: attached PHY driver [Broadcom
BCM63XX (1)] (mii_bus:phy_addr=bcm63xx_enet-0:01, irq=17)
Pluging and uplugging the ethernet cable now generates interrupts and the
PHY goes up and down as expected.
Signed-off-by: Daniel González Cabanelas <[email protected]>
---
drivers/net/ethernet/broadcom/bcm63xx_enet.c | 7 +++++++
1 file changed, 7 insertions(+)
diff --git a/drivers/net/ethernet/broadcom/bcm63xx_enet.c
b/drivers/net/ethernet/broadcom/bcm63xx_enet.c
index fd876721316..0dad527abb9 100644
--- a/drivers/net/ethernet/broadcom/bcm63xx_enet.c
+++ b/drivers/net/ethernet/broadcom/bcm63xx_enet.c
@@ -1819,7 +1819,14 @@ static int bcm_enet_probe(struct platform_device *pdev)
bus->phy_mask = ~(1 << priv->phy_id);
if (priv->has_phy_interrupt)
+ phydev = mdiobus_get_phy(bus, priv->phy_id);
+ if (!phydev) {
+ dev_err(&dev->dev, "no PHY found\n");
+ goto out_unregister_mdio;
+ }
+
bus->irq[priv->phy_id] = priv->phy_interrupt;
+ phydev->irq = priv->phy_interrupt;
ret = mdiobus_register(bus);
if (ret) {
--
2.30.1