On Tue, Nov 27, 2007 at 09:40:08AM -0800, Kok, Auke wrote:
> > I'm afraid, I'm missing the point as you have stated that in-kernel drivers
> > have problem with suspicious board hang...
> 
> my mistake, sorry for that confusion.
> 
> the fake hangs on 82562/6 devices occur on 10mbit link only. You can check in 
> the
> code for a line that says:
> 
>       adapter->tx_timeout_factor = 8;
> 
> change that number to 16 to cope with the problem on 10mbit link partners.
> However this won't fix the issue on 100mbit partners and we need to
> investigate that if that is the case.

100mbit is the issue in my case.

-- 
Lukáš Hejtmánek
-
To unsubscribe from this list: send the line "unsubscribe netdev" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to