Hi David,

Could this be an issue with pause frames? At a previous job I remember having issues with a similar configuration using two broadcom sb1250 3 gigE port devices. If I ran bidirectional tests on a single pair of ports connected via cross over, it was slower than when I gave each direction its own pair of ports. The problem turned out to be that pause frame generation and handling was not configured correctly.

We had PAUSE frames turned off for our testing. The idea is to let TCP do the flow and congestion control.

The problem with PAUSE+TCP is that it can cause head-of-line blocking, where a single oversubscribed output port on a switch can PAUSE a large number of flows on other paths.

Cheers,
        Bruce
--
To unsubscribe from this list: send the line "unsubscribe netdev" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html