Asus Crosshair II Formula is using Marvell 88E8056 PCI-E Gigabit Ethernet Controller. I have installed snv_128 which should have SUNWyge driver integrated. During the boot first NIC comes up OK, but second one fails (skge1):
r...@opensolaris:~# dmesg|grep skge Nov 29 00:52:21 opensolaris skge: SysKonnect Gigabit Ethernet Adapter families v8.19.1.3 Tue Nov 14 10:32:06 GMT 2006 Nov 29 00:52:21 opensolaris pcieb: [ID 586369 kern.info] PCIE-device: pci1043,8...@0, skge0 Nov 29 00:52:21 opensolaris genunix: [ID 936769 kern.info] skge0 is /p...@0,0/pci10de,7...@14/pci1043,8...@0 Nov 29 00:52:21 opensolaris skge: [ID 801593 kern.notice] skge0: Marvell Yukon 88E8056 Gigabit Ethernet Controller Nov 29 00:52:21 opensolaris skge: [ID 200860 kern.notice] PreferredPort: A Nov 29 00:52:21 opensolaris skge: [ID 834597 kern.notice] Dual Net Support: No Nov 29 00:52:21 opensolaris skge: [ID 389192 kern.notice] RLMT Mode: CLS Nov 29 00:52:21 opensolaris skge: [ID 573059 kern.notice] Jumbo Frame Support: Off Nov 29 00:52:21 opensolaris skge: [ID 772773 kern.notice] Copy Threshold: 1500 Nov 29 00:52:21 opensolaris skge: [ID 477694 kern.notice] VLAN Support: No Nov 29 00:52:21 opensolaris skge: [ID 571159 kern.notice] Interrupt Moderation: On Nov 29 00:52:21 opensolaris skge: [ID 100000 kern.notice] Nov 29 00:52:22 opensolaris ip: [ID 741211 kern.error] skge1: DL_ATTACH_REQ failed: DL_BADPPA Nov 29 00:52:22 opensolaris ip: [ID 842151 kern.error] skge1: DL_BIND_REQ failed: DL_OUTSTATE Nov 29 00:52:22 opensolaris ip: [ID 631543 kern.error] skge1: DL_PHYS_ADDR_REQ failed: DL_OUTSTATE Nov 29 00:52:22 opensolaris ip: [ID 474580 kern.error] skge1: DL_UNBIND_REQ failed: DL_OUTSTATE Nov 29 00:52:24 opensolaris skge: [ID 418734 kern.notice] skge0: Network connection up on port A Nov 29 00:52:24 opensolaris skge: [ID 249518 kern.notice] Link Speed: 1000 Mbps Nov 29 00:52:24 opensolaris skge: [ID 966250 kern.notice] Autonegotiation: Yes Nov 29 00:52:24 opensolaris skge: [ID 676895 kern.notice] Duplex Mode: Full Nov 29 00:52:24 opensolaris skge: [ID 825410 kern.notice] Flow Control: Symmetric Nov 29 00:52:24 opensolaris skge: [ID 512437 kern.notice] Role: Slave Looks like that /etc/path_to_inst has only 1 instance, shouldn't there be 2 (one for each NIC)? r...@opensolaris:~# cat /etc/path_to_inst|grep skge "/p...@0,0/pci10de,7...@14/pci1043,8...@0" 0 "skge" I tried booting the computer to rediscover the device tree, but still shows only 1 skge instance in /etc/path_to_inst My question is how to get 2nd skge NIC to work? -- This message posted from opensolaris.org _______________________________________________ networking-discuss mailing list [email protected]