I believe this is also the same on the 7600 platform running SUP720's unless I'm confusing something. NDE on 6500 and 7600 is pretty worthless in general without TCP flags anyway.
> Tristan RHODES wrote: >> We are seeing these errors on our Cisco 6500 with Sup720 modules. It >> looks like we might be processing more flows than it can handle. >> >> Dec 4 18:10:59: %EARL_NETFLOW-SP-4-TCAM_THRLD: Netflow TCAM threshold >> exceeded, TCAM Utilization [93%] > > IIRC, you can't do anything - (sampled) netflow is horribly broken on > the 6500s, where data will be stored in TCAM _before_ sampling, so even > if you just wanted 1/1000 sampled data, you'd still overflow TCAM once > your netflow-observed interfaces pass enough traffic... > > someone with more cisco background should clarify that though, that's > just second-hand information. ------------------------------------------------------------------------- SF.Net email is sponsored by: The Future of Linux Business White Paper from Novell. From the desktop to the data center, Linux is going mainstream. Let it simplify your IT future. http://altfarm.mediaplex.com/ad/ck/8857-50307-18918-4 _______________________________________________ Nfsen-discuss mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/nfsen-discuss