I believe this is also the same on the 7600 platform running SUP720's unless
I'm confusing something.  NDE on 6500 and 7600 is pretty worthless in
general without TCP flags anyway.

> Tristan RHODES wrote:
>> We are seeing these errors on our Cisco 6500 with Sup720 modules.  It
>> looks like we might be processing more flows than it can handle.
>>
>> Dec  4 18:10:59: %EARL_NETFLOW-SP-4-TCAM_THRLD: Netflow TCAM threshold
>> exceeded, TCAM Utilization [93%]
> 
> IIRC, you can't do anything - (sampled) netflow is horribly broken on
> the 6500s, where data will be stored in TCAM _before_ sampling, so even
> if you just wanted 1/1000 sampled data, you'd still overflow TCAM once
> your netflow-observed interfaces pass enough traffic...
> 
> someone with more cisco background should clarify that though, that's
> just second-hand information.



-------------------------------------------------------------------------