Hello,

We are using nfsen 1.3.6p1 with nfdump 1.6.6 (on CentOS 5) with great 
success (thank you).

We have just upgraded two Cisco 3825 routers from IOS version 12.4(9)T2 
to 12.4(24)T8 (Advanced Enterprise).

Until now (with v12.4(9)T2), netflow was working fine in nfsen.

With the new version we were seeing very strange behavior. Stats were 
not correct.

I followed directions I found on the Internet and changed from standard 
(old-fashioned) netflow export to "Flexible Netflow" and now stats seem 
to be correct, EXCEPT Packet Stats.

Packet Stats seem to be magnified by a very large factor, est. at 
100,000 (100K). That is, when the real packet traffic is at 100 
packets/sec, the stats show it as 10M/s (approximate estimation)!

Can you please help me in identifying the cause of this behavior and 
suggest a solution?

I've tried my best until now, but I'm at a loss.

I will send to Peter directly a zip file with a full (5 min) capture 
from our two routers, hoping it will help in tracing the problem.

For reference here is the current config:

        flow exporter IPv6
          destination 195.251.xxx.xxx
          source Loopback0
          transport udp 9995
        !
        flow exporter IPv4
          destination 195.251.xxx.xxx
          source Loopback0
        !
        flow monitor IPv6
          record netflow ipv6 original-output
          exporter IPv6
          transport udp 9995
        !
        flow monitor IPv4
          record netflow ipv4 original-output
          exporter IPv4
        !

    And on each interface:

        ip flow monitor IPv4 input
        ipv6 flow monitor IPv6 input

Thanks in advance,
Nick

------------------------------------------------------------------------------
_______________________________________________
Nfsen-discuss mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/nfsen-discuss

Reply via email to