[ https://issues.apache.org/jira/browse/IOTDB-5142?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17644589#comment-17644589 ]
Xingyu Liu commented on IOTDB-5142: ----------------------------------- 该问题复现成功。 使用代码如下: {code:go} package main import ( "github.com/apache/iotdb-client-go/client" ) func main() { host := "127.0.0.1" port := "6667" user := "root" password := "root" config := &client.Config{ Host: host, Port: port, UserName: user, Password: password, } session := client.NewSession(config) session.Open(false, 0) // session.Close() } {code} {{{}如果调用{}}}session.Close()则一切正常,如果不调用session.Close(),就会导致连接重置。 由于程序结束前未调用关闭接口,服务器连接不上就会尝试重置连接,由于session已经丢失就会连接失败,所以会报错。 想要解决此问题,需要将不再使用的session及时关闭。 > go-client connection reset problem > ---------------------------------- > > Key: IOTDB-5142 > URL: https://issues.apache.org/jira/browse/IOTDB-5142 > Project: Apache IoTDB > Issue Type: Bug > Components: Client/Others > Reporter: Xingyu Liu > Assignee: Xingyu Liu > Priority: Major > Attachments: image-2022-12-08-11-07-55-398.png, > image-2022-12-08-11-09-00-848.png, image-2022-12-08-11-09-05-286.png > > > 现在有台服务器大量报连接重置 > !image-2022-12-08-11-07-55-398.png! > !image-2022-12-08-11-09-00-848.png! > !image-2022-12-08-11-09-05-286.png! > 问题:go client会在每天0点左右重连,但是其中zoneId参数为空,前几天是0点左右,刚发现了9点也有一条,看来和时间无关 -- This message was sent by Atlassian Jira (v8.20.10#820010)