eugenegujing commented on code in PR #8936:
URL: https://github.com/apache/texera/pull/8936#discussion_r4520528242


##########
frontend/src/app/workspace/service/execute-workflow/execute-workflow.service.spec.ts:
##########
@@ -238,6 +245,171 @@ describe("ExecuteWorkflowService", () => {
     });
   });
 
+  describe("losing the selected computing unit mid-run", () => {
+    const unit = (cuid: number): DashboardWorkflowComputingUnit =>
+      ({ computingUnit: { cuid }, status: "Running" }) as unknown as 
DashboardWorkflowComputingUnit;
+
+    it("ends a running execution when the selection empties", () => {
+      const enable = vi.spyOn(service["workflowActionService"], 
"enableWorkflowModification");
+      const seen: ExecutionState[] = [];
+      service.getExecutionStateStream().subscribe(({ current }) => 
seen.push(current.state));
+      emitWsEvent({ type: "WorkflowStateEvent", state: ExecutionState.Running 
});
+      emitWsEvent({ type: "WorkerAssignmentUpdateEvent", operatorId: "op1", 
workerIds: ["w1", "w2"] });
+      selectedUnit$.next(unit(7));
+      enable.mockClear();
+
+      selectedUnit$.next(null);
+
+      
expect(service.getExecutionState().state).toBe(ExecutionState.Uninitialized);
+      expect(service.getWorkerIds("op1")).toEqual([]);
+      expect(enable).toHaveBeenCalled();
+      expect(seen).toEqual([ExecutionState.Running, 
ExecutionState.Uninitialized]);
+    });
+
+    it("ends a paused execution when the selection empties", () => {
+      emitWsEvent({ type: "WorkflowStateEvent", state: ExecutionState.Running 
});
+      emitWsEvent({ type: "WorkflowStateEvent", state: ExecutionState.Paused 
});
+      selectedUnit$.next(unit(7));
+
+      selectedUnit$.next(null);
+
+      
expect(service.getExecutionState().state).toBe(ExecutionState.Uninitialized);
+    });

Review Comment:
   Done in 8d8847ef1cdd891cdea381d8e7937115e3313b11. All of them: 
   - Removed the standalone Paused, finished-execution, no-execution, 
error-messages and clock tests.
   - The switch, first-selection and status cases are one table. Failed moved 
out of it into two tests of its own, since it now resets, and the table gained 
a row for a unit that is still Running with the socket down.
   - The four Kill tests and the old two-row table are one six-row `it.each`.



-- 