On 03/02/2013 21:07, Marcin Slusarz wrote:
Current uninitialized sensor detection does not work for me on nv4b and
sensor returns crazy values (>190°C). It stabilises later, but it's too
late - therm code shutdowns the machine...
Let's just reset it on init.
Signed-off-by: Marcin Slusarz <marcin.slus...@gmail.com>
Hmm, so it means the bios initializes your sensor at POST. This was not
the case on mine and we used to rely on the fact that nv4x's sensor was
not initialized.
Anyway, forcing a reset is not a bad idea. Please add my signed-off-by.
Thanks for your ptherm patchset :)