Hi Anthony,

nox doesn't keep any flow entries, the flow entries are on the switch. I am
guessing that you are asking how to make those entries stay on the switch
permanently?
If so, that can be done by setting the hard_timeout to 0 in the flow_mod

On Fri, Jun 29, 2012 at 5:25 AM, Anthony Salim <
[email protected]> wrote:

> Hi guys,
>
> From what i know, nox only keep the table within certain time period, my
> question is how do we keep the flows that we want permanently? Thanks.
>
> Regards,
> Anthony
>

Reply via email to