Hi Syed, type=3 corresponds to "OFPET_FLOW_MOD_FAILED", and code=0 to "OFPFMFC_ALL_TABLES_FULL"
Any reason why the flow table would be indeed full? On Wed, Jan 12, 2011 at 3:45 PM, Syed Akbar Mehdi < akbar.me...@seecs.nust.edu.pk> wrote: > Hi, > > While running some captured network data through an openflow switch running > on a Linux box, I get the following error messages at the controller: > > 00015|openflow-event|ERR:received Openflow error packet from > dpid=002320b77f72: type=3, code=0, 80 bytes of data > > What is meant by the type = 3, code = 0 ? Also does the 80 bytes mean that > the packet at the switch that caused it to send this error to the controller > was 80 bytes in size? > > -- > Regards, > Syed Akbar Mehdi, > School of EECS (SEECS), > National University of Sciences and Technology (NUST), > Pakistan. > > > _______________________________________________ > nox-dev mailing list > nox-dev@noxrepo.org > http://noxrepo.org/mailman/listinfo/nox-dev_noxrepo.org > >
_______________________________________________ nox-dev mailing list nox-dev@noxrepo.org http://noxrepo.org/mailman/listinfo/nox-dev_noxrepo.org