Hi Hans,

I noticed a regression when rebuilding one of my teaching documents with 
ConTeXt LMTX 2026.10.25.

Minimal example:

\starttext
200\unit{micro Volt}
\stoptext

Expected output: 200µV

Actual output: 200V (the micro prefix disappears).

The log reports:

fonts > checking > char µ (U+000B5) in font 'LMRoman10-Regular' with id 1: 
missing

In `phys-dim.lmt`, the `micro` prefix appears to be defined twice, first as 
`\mu` and later as the literal character `µ` (U+00B5).

The following workaround fixes the problem:

\setupprefixtext[en][micro=μ]

This uses U+03BC, which is present in Latin Modern Roman.

Perhaps the unit prefix handling could provide a fallback for fonts that don't 
contain U+00B5?

Best regards,