Matthias,

You can either enable the dynamic interfaces creation on the ntopng side (e.g., 
on the basis of the  %EXPORTER_IPV4_ADDRESS) or you can run two separate 
nprobes, one per stream, and then send the results to two ntopng interfaces.

Regard,
Simone

> On 10 Dec 2017, at 15:39, Matthias Henze <li...@mhcsoftware.de> wrote:
> 
> Hi,
> 
> currently I use 2 routers for my 2 uplinks. Now I've a new router witch is 
> able to handle 2 uplinks. The new router sends one NetFlow stream. I can 
> configure it to send NetFlow data for both uplinks. How to configure Nprobe 
> and Ntop to get two interfaces in Ntop?
> 
> TIA
> Matthias
> 
> 
> -- 
> 
> MHC SoftWare GmbH
> Fichtera 17
> 96274 Itzgrund/Germany   
> voice: +49-(0)9533-92006-0
> fax: +49-(0)9533-92006-6
> e-mail: i...@mhcsoftware.de
> 
> HR Coburg: B2242
> Geschaeftsfuehrer: Matthias Henze
> 
> 
> 
> _______________________________________________
> Ntop mailing list
> Ntop@listgateway.unipi.it
> http://listgateway.unipi.it/mailman/listinfo/ntop