Hello Satish,

We have users doing 20+ Gbps with sFlow using the combination of nProbe + 
ntopng. sFlow is a sampling technology so, assuming sampling rates are 
configured opportunely, you won't have any issue.

See https://blog.sflow.com/2009/06/sampling-rates.html for recommended sampling 
rates.

For a guide on how to setup the collection using nProbe and ntopng see this 
blog post: 
https://www.ntop.org/nprobe/sflow-collection-and-analysis-with-nprobe-and-ntopng/

Simone

> On 21 Mar 2019, at 17:45, Satish Patel <satish....@gmail.com> wrote:
> 
> Folks,
> 
> We have 60Gbps peak bandwidth usage on our public with ISP and now i
> want to monitor data usage with sFlow and wanted understand that does
> ntopng can handle that level of traffic or sample rate?
> 
> Do i need any special configuration to handle this?
> Do i need special hardware ?
> 
> Any suggestions would be appreciated.
> _______________________________________________
> Ntop mailing list
> Ntop@listgateway.unipi.it
> http://listgateway.unipi.it/mailman/listinfo/ntop

_______________________________________________
Ntop mailing list
Ntop@listgateway.unipi.it
http://listgateway.unipi.it/mailman/listinfo/ntop

Reply via email to