On non-network devices you should probably only ever alert on the artificial “average” processor entity.
I’d recommend a delay for more purposes too, as things will be >95% occasionally quite often. Adam. From: Michael via observium <observium@lists.observium.org> Sent: 24 August 2022 13:53 To: observium@lists.observium.org Cc: Michael <mi...@gmx.de> Subject: [Observium] Help with Alert Checker again / Multiprocessor System Hey List, after fixing the problem with dont check mountpoints, here´s the next one ... we´ve a Server with 2 CPU; I defined an Alert Checker Entity DeviceHostname Match "*" and Condition "processor_usage gt 95" ... Now, when I look into my Alert Checkers, I see my Server with Processor "Average" and 2 times "Intel Xeon Processorname ... " that confuses me a little ... and now the actual Problem: When Observium send an Alert-Mail, I get 3 Mails ... 1 for "Average" and one for each Processor ... but actually it is enough if I only get one Email ... can I configure this somewhere ? I helped myself by extend the Entity with "Processor_Description notmatch *average" ... but I don´t know if this is the right way ... Can somebody help here? Thanks in advance. Regards, Michael