It seems 3 issues there.

1. The issue in step 2 is indeed as Regina said, same as 100616.

2. The issue in step 3 is about the view switch. It shows the master
slide thumbnails when switch view from Handout to Outline.
The root cause may be as below:
a.The Handout view is regarded that equal to a Master view. The
judgement changes the content in thumbnail slide area into master
slide pages. But the thumbnail slide area does not display in Handout
view, so we can not see the effect in UI.
b.Outline view does not refresh the thumbnail slide content. When
switch from Handout to Outline view, it inherited the previous
setting.

3. The freeze issue I've not reproduced sucessfully. Would you pls
provide more context?

Regards,
Shan Zhu


2012/8/1 Shenfeng Liu <liush...@gmail.com>

> 120428 created for this issue:
> https://issues.apache.org/ooo/show_bug.cgi?id=120428
>
> - Shenfeng
>
>
> 2012/8/1 Andre Fischer <awf....@gmail.com>
>
> > On 01.08.2012 09:27, Shenfeng Liu wrote:
> >
> >> Hi, all,
> >>    I Installed r1366353 Windows for both en-US and zh-CN. Basically they
> >> works well. Only one thing seems to be a big problem: the Handout view
> >> display only a blank slide. It also happens in 3.4.0, so not a
> regression.
> >> I'm not sure if it is a designed behavior.
> >>
> >>    Steps to reproduce are very simple:
> >> 1. Create a presentation with built-in template.
> >> 2. Switch to Handout view.  Issue: you will notice that the handout view
> >> display only a blank slide.
> >> 3. Related issue: if you switch from Handout view to Outline view, there
> >> will be only 1 slide left in the slide navigator.
> >> 4. Not sure if related: it happened twice that when I switch quickly
> >> between views, AOO freeze on the Outline view.
> >>
> >
> > I hope that freezing is nowhere a designed behavior :-)
> >
> >
> >     If it is not a designed behavior, I will open a defect in BZ.
> >>    Thanks!
> >>
> >
> > Please do so.
> >
> > -Andre
> >
> >
> >> - Shenfeng
> >>
> >>
> >
>

Reply via email to