Hi,
I debugged the integrated login and compared it with a running one.
Differences:
AFS AfsLogon - Test Service Running Return Code[1] ?Running[0]
instead of
AFS AfsLogon - Test Service Running Return Code[2] ?Running[0]
and
AFS AfsLogon - Test Service Start Pending Return Code[1] ?Start
Pending[0]
instead of
AFS AfsLogon - Test Service Start Pending Return Code[2] ?Start
Pending[0]
After this the Afs-Logon is stopped. After logout new logins are
successfully.
I don't know, where the problem could be.
Thanks,
Lars
Jeffrey Altman wrote:
the information for debugging the Integrated Logon module
is described in the OpenAFS for Windows Release Notes.
--