Hi
On 26.07.2015 20:02, Sipos Csaba wrote:
> I will try to give you as many feedback as possible. :-)
>
> I finally have a more or less working setup. At least there is no crash
> whatsoever, and the PS domain is working, the UE can attach, activate PDP,
> transfer data to some extent.
>
> For example when i tried to ping the TUN interface, I got 2500-2600ms latency.
That's normal in the default case, since the MS will have to issue a
RACH to get an uplink TBF for the response. You can allow to keep the
PACCH open for a longer time by configuring
pcu
dl-tbf-idle-time 2000
This keeps the DL TBF open for the time given (in ms) by periodically
sending LLC dummy commands.
HTH
Jacob
--
- Jacob Erlbeck <[email protected]> http://www.sysmocom.de/
=======================================================================
* sysmocom - systems for mobile communications GmbH
* Alt-Moabit 93
* 10559 Berlin, Germany
* Sitz / Registered office: Berlin, HRB 134158 B
* Geschaeftsfuehrer / Managing Directors: Holger Freyther, Harald Welte