On 15/09/17 09:52, mohammad nejati wrote:
Hi ,

OsmoBTS version 0.6.0.6-ae13
OpenBSC version 0.15.0.885-968a6

I flow the instructions from wiki page and create config files :

https://osmocom.org/projects/cellular-infrastructure/wiki/SDR_OsmoTRX_network_from_scratch

but when i run :
osmo-nitb -c ~/.osmocom/open-bsc.cfg -l ~/.osmocom/hlr.sqlite3 -P -C
--debug=DRLL:DCC:DMM:DRR:DRSL:DNM

I got this error :

There is no such command.
Error occurred during reading the below line:
  timer t3103 0

<0005> ../../../src/libbsc/bsc_init.c:536 Failed to parse the config
file: '/home/ashtum/.osmocom/open-bsc.cfg'
Reading config failed. Exiting.


I think there was a change a few weeks ago which prevents configuration to set any timer to 0. I think you are safe removing that line and trying again, and as far as I know the program will provide a sane timer value.



Similarly when i run :

osmo-bts-trx -c ~/.osmocom/osmo-bts.cfg


I got :

((*))
   |
  / \ OsmoBTS
There is no such command.
Error occurred during reading the below line:
  fn-advance 20

% rtp bind-ip is now deprecated
Failed to parse the config file: '/home/ashtum/.osmocom/osmo-bts.cfg'


According to osmo-bts code:
"osmotrx fn-advance <0-30>"
So I'd say you need something like this:
phy 0
  osmotrx fn-advance 20

The config from that wiki page seems old and not matching the current schema. Please have a look at an up to date config and merge it with the required bits to work with your hardware: https://git.osmocom.org/osmo-bts/tree/doc/examples/trx/osmo-bts.cfg

Feel free to update the wiki or provide here a working config once you are successful.

--