Hi,
I'm attempting to create a GUI application as the main application for
an OpenCPI based system.  Looking at the documentation, in order to
route test/debug data to the main app I need to connect the main app to
an RCC worker port using an external port.

My app creates the workers and connection using the XML string method,
however I can't seem to connect up an external port using this method.
There is an example in Hello App:

"  <connection>"
"    <external name='out'/>"
"    <port instance='hello' name='out'/>"
"  </connection>" 

But trying to replicate this in my main app XML string...
"  <connection>"
  "    <external name='data'>"
  "    <port instance='process_results' name='data'/>"
"  </connection>"
 ...yields the error: "Error parsing assembly xml string due to: no
ports found under connection". 

The XML body and spec of my component are below. 

<RccImplementation controloperations="start">
  <xi:include href="process_results_spec.xml"/>
</RccImplementation> 

<ComponentSpec Name="process_results">
  <DataInterfaceSpec Name="data" Producer="false">
    <xi:include href="stream_protocol.xml"/>
  </DataInterfaceSpec>
</ComponentSpec> 

So to be specific: 

1. Does the external port need to be declared in the component spec /
body and if so what is the syntax used?
2. What is the syntax used in the main app XML to connect to the
external port (assuming the above is incorrect)? 

Many thanks,
  Nigel Merritt 


IMPORTANT: This email remains the property of the Department of Defence
and is subject to the jurisdiction of section 70 of the Crimes Act 1914.
If you have received this email in error, you are requested to contact
the sender and delete the email. 


_______________________________________________
opencpi_dev mailing list
[email protected]
http://lists.opencpi.org/listinfo.cgi/opencpi_dev-opencpi.org

Reply via email to