Hi, The counters can be reset by setting OFPFF_RESET_COUNTS flag in FLOW_MOD message (command : Modify).
For reference, openflow-spec-1.2 Page no 23: "If the OFPFF_RESET_COUNTS flag is set, the flow entry counters must be cleared." Regards, Pragyan On Tue, Dec 4, 2012 at 2:34 AM, Liyuan Wang <wangliyuan...@gmail.com> wrote: > Hi all, > > Anyone know the code to reset the counter? Or which page on Openflow-spec > has this information? > I don't want to re-install the entries. > Just want to set the counter to 0 again. > > Thanks and regards, > Liyuan > > _______________________________________________ > openflow-discuss mailing list > openflow-discuss@lists.stanford.edu > https://mailman.stanford.edu/mailman/listinfo/openflow-discuss > >
_______________________________________________ openflow-discuss mailing list openflow-discuss@lists.stanford.edu https://mailman.stanford.edu/mailman/listinfo/openflow-discuss