On Wed, Feb 25, 2015 at 10:50:01AM +0100, ???????????? wrote:
> First one, In the section of "Learn Development Tools", when I set-up the
> switch by adding new flows using the cmd "ovs-ofctl add-flow s1
> in_port=1,actions=output:2" and "ovs-ofctl add-flow s1
> in_port=2,actions=output:1", the two entries seem never expire in the
> switch, but according to the tutorial, they owe to disappear after the
> default duration (60 s), so I really cannot understand this.

ovs-ofctl doesn't have a default idle_timeout or hard_timeout.  If the
tutorial says that it does, it's wrong.

I don't have any idea about your other question.