On Thu, May 28, 2015 at 10:16:00AM +0000, saifullah M A wrote: > 1. Can I have my own counters other than the list of specified counters in > the openflow specification 1.1?
No. > 2. what is the maximum number of counters I can add per each entry in a flow > table? Two: flow entries have byte and packet counters. > 3. Can I have my have own entries in the group table like 32 bit ipAddress of > a host as the groupId? You can pick your own group_id, and group_ids are 32-bit numbers, so I guess you could use an IP address. > 4. What is the maximum number of groupIds I can have in the group table? Depends on the switch. _______________________________________________ openflow-discuss mailing list openflow-discuss@lists.stanford.edu https://mailman.stanford.edu/mailman/listinfo/openflow-discuss