On Thu, May 28, 2015 at 10:16:00AM +0000, saifullah M A wrote:
> 1. Can I have my own counters other than the list of specified counters in 
> the openflow specification 1.1?

No.

> 2. what is the maximum number of counters I can add per each entry in a flow 
> table?

Two: flow entries have byte and packet counters.

> 3. Can I have my have own entries in the group table like 32 bit ipAddress of 
> a host as the groupId?

You can pick your own group_id, and group_ids are 32-bit numbers, so I
guess you could use an IP address.

> 4. What is the maximum number of groupIds I can have in the group table?

Depends on the switch.
_______________________________________________
openflow-discuss mailing list
openflow-discuss@lists.stanford.edu
https://mailman.stanford.edu/mailman/listinfo/openflow-discuss

Reply via email to