Thanks Luis,

I did try re-producing this manually but couldn't.

On Mon, Aug 29, 2016 at 4:36 PM, Luis Gomez <[email protected]> wrote:

> Actually I think I figured out the issue with l2switch basic csit: For
> some reason after we changed to new OF plugin (old plugin is fine) the
> l2switch app does not work very well when mininet disconnect + reconnect
> with no time in-between.
>
> To probe this I added some sleep (2 secs) between disconnect and connect
> mininet between tests, and after that the tests pass with no issues:
>
> https://git.opendaylight.org/gerrit/#/c/44799/
> https://jenkins.opendaylight.org/sandbox/job/l2switch-csit-
> 1node-switch-only-boron/5/
>
> So I opened this bug to track the new behavior:
>
> https://bugs.opendaylight.org/show_bug.cgi?id=6575
>
> I am not sure how critical is this as most users trying l2switch manually
> will not notice anything.
>
> BR/Luis
>
>
> > On Aug 29, 2016, at 10:30 AM, Luis Gomez <[email protected]> wrote:
> >
> > Hi l2switch devs,
> >
> > Here is my analysis on CSIT failures:
> >
> > - Address Tracking and Loop Removal test issues are not reproducible
> outside ODL infra, therefore these are not blocker and maybe not even bugs.
> Still some infra investigation is required here as same tests are passing
> for Beryllium.
> >
> > - Issue with host scalability is due to recent regression: l2switch does
> not push flood flows on single switch: https://bugs.opendaylight.org/
> show_bug.cgi?id=6573
> >
> > BR/Luis
> >
> >
>
> _______________________________________________
> openflowplugin-dev mailing list
> [email protected]
> https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev
>
_______________________________________________
openflowplugin-dev mailing list
[email protected]
https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev

Reply via email to