On Thu, 2004-12-23 at 11:07 +0200, Tziporet Koren wrote:
> Hi, 
> We found an issue with the FW that causing this overrun. 
> The bug happened when incrementing CQ consumer index in more then 1
> and a CQE is written at the same time on this CQ. 
> This bug is the same in 3.3.1 and 4.6.1 versions.
> 
> A FW with a fix will be provided next week.

Can these firmware revs be checked in somewhere?  Or put on the OpenIB
website?

I don't even have tavor 3.3.1 or arbel 4.6.1.

Thanks,

-tduffy

Attachment: signature.asc
Description: This is a digitally signed message part

_______________________________________________
openib-general mailing list
[email protected]
http://openib.org/mailman/listinfo/openib-general

To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general