Quoting r. Ralph Campbell <[EMAIL PROTECTED]>:
> Subject: [PATCH] change Mellanox SDP workaround to a moduleparameter
> 
> This patch changes the hardwired MTU limit of 1024 in SDP
> into a module parameter so it can be disabled for HCAs
> without the RC performance problem.
> 
> Signed-off-by: Ralph Campbell <[EMAIL PROTECTED]>

I thought about it some more: what happens if nodes with different
max MTU values try to connect?

My understanding of the spec:

- passive side should send REJ indicating error and passing the
  maximum MTU it supports
- active side should retry the connection with a lower MTU

Right?
By the way, this handling seems to be missing in CMA.

-- 
Michael S. Tsirkin
Staff Engineer, Mellanox Technologies
_______________________________________________
openib-general mailing list
[email protected]
http://openib.org/mailman/listinfo/openib-general

To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general

Reply via email to