This is an oversight. It will be fixed in the next major version of the LSI Logic Storage controller firmware. The OUI after the fix will be A0B8.
Timothy Snider Storage Architect Strategic Planning, Technology and Architecture LSI Logic Corporation 3718 North Rock Road Wichita, KS 67226 (316) 636-8736 [EMAIL PROTECTED] -----Original Message----- From: Roland Dreier [mailto:[EMAIL PROTECTED] Sent: Wednesday, July 26, 2006 2:05 PM To: Michael S. Tsirkin Cc: Vu Pham; openib-general@openib.org Subject: Re: [PATCH] RFC: srp filesystem data corruption problem/work-around > I'll fix that up to check the OUI. Makes sense. Unfortunately at least the Engenio target I have access to uses the same Mellanox OUI: IO Unit Info: port LID: 0003 port GID: fe800000000000000002c902004000e6 change ID: 0002 max controllers: 0x10 controller[ 1] GUID: 0002c902004000e4 vendor ID: 0002c9 device ID: 005a44 IO class : 0100 ID: LSI Storage Systems SRP Driver 200400a0b80bdd41 service entries: 1 service[ 0]: 200400a0b80bdd41 / SRP.T10:200400A0B80BDD41 but still I think it's better than nothing to only activate the workaround for GUIDs starting with 0002c9. - R. _______________________________________________ openib-general mailing list openib-general@openib.org http://openib.org/mailman/listinfo/openib-general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general