Blinking led's is a "nice to have", but if your server supports ipmi and ses, the fault management report has already located the disk.

So I need to replace the disk in ses-enclosure=1/bay=6/disk=0


Apr 15 2010 22:25:27 abbbe612-1131-6add-f5c9-8537ecb46dc7 DISK-8000-0X
  100%  fault.io.disk.predictive-failure
Problem in: hc://:product-id=LSILOGIC-SASX36-A.1:server-id=:chassis-id=50030480005a337f:serial=6
XW15V2S:part=ST32000542AS-ST32000542AS:revision=CC34/ses-enclosure=1/bay=6/disk=0
Affects: dev:///:devid=id1,sd@n5000c50021f4916f//pci@0,0/pci8086,4023@3/pci15d9,a680@0/sd@24,
0
FRU: hc://:product-id=LSILOGIC-SASX36-A.1:server-id=:chassis-id=50030480005a337f:serial=6
XW15V2S:part=ST32000542AS-ST32000542AS:revision=CC34/ses-enclosure=1/bay=6/disk=0
          Location: 006

Mark.