--On Friday, April 26, 2013 8:07 PM +0000 [email protected] wrote: > Full_Name: Al F > Version: 2.4.35 > OS: Redhat 6.4 - x64 > URL: https://dl.dropboxusercontent.com/u/982376/its/al-f-130426.zip > Submission from: (NULL) (74.123.146.10) > > > Hi, I have a multimaster system utilizing delta-sync for replication. The > system is utilizing mdb for both the user and the accesslog data. I have > ppolicy & memberof overlays enabled as well. all of my writes are > directed at a single server using a load balancer. I have found that > when a user has a pwdFailureTime attribute set on their entry, if an > administrator resets the password, "null_callback : error code 0x10" is > produced in the log on the secondary system and the secondary system goes > into refresh mode.
Hello, I believe this is the same as ITS#8927, which has been fixed for the upcoming OpenLDAP 2.4.47 release. Warm regards, Quanah -- Quanah Gibson-Mount Product Architect Symas Corporation Packaged, certified, and supported LDAP solutions powered by OpenLDAP: <http://www.symas.com>