On Sun, Aug 23, 2009 at 10:17 AM, Sven Rebhan<[email protected]> wrote:
> This patch fixes a typo in the voltage setting of LDO1.
> In the function mangle_pmu_pdata_by_system_rev() the value of min_uV
> is set twice, while the value of max_uV stays at the initialized
> value. This leaves us with .constraints.min_uV = 3300000 and
> .constraints.max_uV = 1300000, which is probably not what we want.
>
> This patch is only required on andy-tracking.

Sent.

N.-