On Sat, 2009-11-14 at 12:45 -0600, Dean Glazeski wrote:
> Hi all,
> 
> It appears that with Zach's recent command handler work the MWW
> command broke.  The reason is because of how the args pointer is
> modified (incremented in this case) as the function executes.  It then
> uses the CMD_NAME macro and this retrieves 'phys' instead of 'mww'.
> In addition, it appears that the command name is now 'ocd_mww', so the
> index for the w, h, or b character now needs to be 6 instead of 2.
> Patch is attached.

Whoops.  Thanks for catching this.  That was an unexpected consequence,
though I should have realized it when I looked at that routine.  Pushed.

Cheers,

Zach
_______________________________________________
Openocd-development mailing list
[email protected]
https://lists.berlios.de/mailman/listinfo/openocd-development

Reply via email to