On Thursday, January 19 at 11:46AM, Szabó Áron wrote: > > Hi, > > I have to test a rather old Bull card with the OpenSC v0.12.2 on Windows, I > try to retrieve all the stored files by using "SELECT FILE" and "READ BINARY" > APDU commands (after performing a successful authentication by using > "VERIFY"). > > I can easily get the content of the MF (3F00) but I also get the same content > for any other file I select and read. Is it possible that the file ID > parameter of "SELECT FILE" can not be evaluated in my case? As you can see > below, I select and read the 3F00, 17FF, 2F02 and I always got the same > content which is stored in the 3F00 (I checked it with another tool). Any > idea? > > Best regards, > Aron > > --- > > opensc-tool.exe --atr -v > Using reader with a card: OMNIKEY CardMan 3621 0 > Connecting to card in reader OMNIKEY CardMan 3621 0... > Using card driver Default driver for unknown cards. > Card ATR: > 3B 67 00 00 29 20 1A 01 78 90 00 ;g..) ..x.. > > opensc-tool.exe --send-apdu BC:20:00:00:08:XX:XX:XX:XX:XX:XX:XX:XX > Received (SW1=0x90, SW2=0x00) > > opensc-tool.exe --send-apdu BC:A4:00:00:02:3F:00 > Received (SW1=0x90, SW2=0x00) > > opensc-tool.exe --send-apdu BC:B0:00:00:00 > Received (SW1=0x90, SW2=0x00): > 17 FF 06 E4 0E 10 03 DF 0E 2F FF C4 1F 6C 04 71 ........./...l.q > 2F 03 00 80 B0 BB FF E4 2F 02 00 80 B0 BB FF E5 /......./....... > 17 01 14 D4 FF FF FF FF FF FF FF FF FF FF FF FF ................ > [...] > > opensc-tool.exe --send-apdu BC:A4:00:00:02:17:FF > Received (SW1=0x90, SW2=0x00) > > opensc-tool.exe --send-apdu BC:B0:00:00:00 > Received (SW1=0x90, SW2=0x00): > 17 FF 06 E4 0E 10 03 DF 0E 2F FF C4 1F 6C 04 71 ........./...l.q > 2F 03 00 80 B0 BB FF E4 2F 02 00 80 B0 BB FF E5 /......./....... > 17 01 14 D4 FF FF FF FF FF FF FF FF FF FF FF FF ................ > [...] > > opensc-tool.exe --send-apdu BC:A4:00:00:02:2F:02 > Received (SW1=0x90, SW2=0x00) > > opensc-tool.exe --send-apdu BC:B0:00:00:00 > Received (SW1=0x90, SW2=0x00): > 17 FF 06 E4 0E 10 03 DF 0E 2F FF C4 1F 6C 04 71 ........./...l.q > 2F 03 00 80 B0 BB FF E4 2F 02 00 80 B0 BB FF E5 /......./....... > 17 01 14 D4 FF FF FF FF FF FF FF FF FF FF FF FF ................ > [...] > ---
Your log looks like you are using select and read binary in different sessions. I think when opensc-tool is done it resets the card's state by disconnecting (which on some readers means that the card gets unpowered). I haven't used opensc-tool too much, but I know that opensc-explorer has a commandline to enter multiple APDUs in one session. Cheers, Frank.
pgpdXZFTXmEAN.pgp
Description: PGP signature
_______________________________________________ opensc-devel mailing list [email protected] http://www.opensc-project.org/mailman/listinfo/opensc-devel