I have a storage server with snv_134 installed. This has four zfs file systems 
shared with iscsi that are mounted as zfs volumes on a Sun v480.

Everything has been working great for about a month, and all of a sudden the 
v480 has timeout errors when trying to connect to the iscsi volumes on the 
storage server.

The connection between the two is a gigabit crossover cable, so other network 
traffic isn't an issue. HBAs, NICs, and cables in the storage server have been 
troubleshot and are working normally. The only common element here is the Intel 
nic in the v480. It seems to work OK otherwise, but it's the only component in 
this equation that hasn't changed.

What's the consensus on NIC configurations for iscsi? Are errors like this 
common if the MTU is set at the default of 1500?

Any and all comments/opinions are welcome.

Thanks.
-- 
This message posted from opensolaris.org
_______________________________________________
opensolaris-discuss mailing list
opensolaris-discuss@opensolaris.org

Reply via email to